4. HOW TO USE THE POINT TABLE 
4 -  55 
 
(2) Timing chart 
ON
OFF
MEND
(Travel completion)
ON
OFF
CPO (Rough match)
ON
OFF
ST2
(Reverse rotation start)
MD0
(Operation mode
selection 1)
ON
OFF
ON
OFF
TLC (Limiting torque)
Torque limit value
ZP
(Home position return
completion)
ON
OFF
Servo motor
speed
Forward rotation
Reverse rotation
ST1
(Forward rotation start)
ON
OFF
Acceleration time
constant
Home position return speed
Home position return
position data
3 ms or shorter
5 ms or longer
Stopper
Stopper time
[Pr. PC35] [Pr. PT11] [Pr. PC35]
(Note 2)
0 r/min
(Note 1)
 
Note   1.  The following torque limits are enabled. 
 
Input device (0: off, 1: on) 
Limit value status 
Enabled torque limit 
value 
TL1  TL 
0 0    Pr. PT11 
0 1 
TLA  >  Pr. PT11  Pr. PT11 
TLA < Pr. PT11  TLA 
1 0 
Pr. PC35  >  Pr. PT11  Pr. PT11 
Pr. PC35  <  Pr. PT11  Pr. PC35 
1 1 
TLA  >  Pr. PT11  Pr. PT11 
TLA < Pr. PT11  TLA 
 
    2.  TLC turns on when a generated torque reaches a value set with any of [Pr. PA11 Forward rotation torque limit], [Pr. PA12 
Reverse rotation torque limit], or [Pr. PC35 Internal torque limit 2]. 
 
The setting value of [Pr. PT08 Home position return position data] is used as the position address at the 
home position return completion.