6. APPLICATION OF FUNCTIONS
6 - 54
(3) Parameter
Set the parameter as follows:
Item Parameter to be used Setting
Mark detection function
selection
[Pr. PT26]
Set the mark detection function selection as follows:
0 _ _ _: Current position latch function
Mark detection range + (lower
three digits)
[Pr. PC66]
Set the upper limit of the latch data in the current position
latch function. When the roll feed display is enabled, set a
valid range with the travel distance from the starting position.
Set a same sign for [Pr. PC66] and [Pr. PC67]. A different
sign will be recognized as minus sign data.
When changing the direction to address decreasing, change it
from the - side of the mark detection ([Pr. PC68] and [Pr.
PC69]). An incorrect order of the setting will trigger [AL. 37].
Therefore, cycling power may be required after [Pr. PC66] to
[Pr. PC69] are all set.
Mark detection range +
(upper three digits)
[Pr. PC67]
Mark detection range - (lower
three digits)
[Pr. PC68]
Set the lower limit of the latch data in the current position latch
function. When the roll feed display is enabled, set a valid
range with the travel distance from the starting position.
Set a same sign for [Pr. PC68] and [Pr. PC69]. A different
sign will be recognized as minus sign data.
When changing the direction to address increasing, change it
from the + side of the mark detection ([Pr. PC66] and [Pr.
PC67]). An incorrect order of the setting will trigger [AL. 37].
Therefore, cycling power may be required after [Pr. PC66] to
[Pr. PC69] are all set.
Mark detection range - (upper
three digits)
[Pr. PC69]