6. APPLICATION OF FUNCTIONS
6 - 57
(5) Timing chart
Device falling position data
MSD (Mark detection)
MSDH
(Mark detection rising latch
completed)
MSDL
(Mark detection falling latch
completed)
Device rising position data
Current position data
Within 5 ms (Note 1)
Within 5 ms (Note 1)
Within 3 ms
Within 3 ms
0A E
0BF
A
B
E
F
ON
OFF
ON
OFF
ON
OFF
Latch data range
Upper limit value
Latch data range
Lower limit value
0.4 ms or longer
Disabled
(Note 2)
Disabled
(Note 2)
Not changed Not changed
C
D
(Note 3)
Note 1. When MSD (Mark detection) is assigned to the CN1-10 pin with [Pr. PD44], a current position data can be obtained in high
speed (within 0.4 ms). When assigning MSD (Mark detection) to the CN1-10 pin, set "Mark detection fast input signal filter
selection" in [Pr. PD31].
2. The position data will not be changed from the previous value.
3. MSDH (Latch completed at rising edge of mark detection) turns off at the same time as MSDL (Latch completed at falling edge
of mark detection) turns on. Set as MSDL turns on/off within the range of the latch data.
If MSD (Mark detection) was turned on again when the previous falling was out of the valid range,
MSDH (Latch completed at rising edge of mark detection) will not change, but the position data will be
updated. Refer to the following timing chart.
Device falling position data
MSD (Mark detection)
MSDH
(Mark detection rising latch
completed)
MSDL
(Mark detection falling latch
completed)
Device rising position data
Current position data
0A
A
B
ON
OFF
ON
OFF
ON
OFF
Latch data range
Upper limit value
Latch data range
Lower limit value
Not changed
CD
C
D0
Not changed
Disabled

Table of Contents