7. PARAMETERS
7 - 22
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PA19
*BLK
Parameter
writing inhibit
Select a reference range and writing range of the parameter.
For the positioning mode, set [Pr. PA19] to "0 0 A B" to enable read/write the
positioning control parameters ([Pr. PT_ _ ]).
Refer to table 7.4 for settings.
00AAh
Table 7.4 [Pr. PA19] setting value and reading/writing range
PA19
Setting
operation
PA PB PC PD PE PF PT
Other
than
below
Reading
Writing
000Ah
Reading Only 19
Writing Only 19
000Bh
Reading
Writing
000Ch
Reading
Writing
00AAh
(Initial
value)
Reading
Writing
00ABh
Reading
Writing
100Bh
Reading
Writing Only 19
100Ch
Reading
Writing Only 19
10AAh
Reading
Writing Only 19
10ABh
Reading
Writing Only 19

Table of Contents