10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL) 
 
10 -  13 
 
(9)  Point table setting data (command [C] [0], [C] [2], [C] [6], [C] [7], [C] [8], [C] [A], [C] [B]) 
 
Command  Data No.  Description  Setting range 
Control 
mode 
Frame 
length 
CP CL 
[C] [0]  [0] [1] to [1] [F]  Writing position data of each point table 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
-999999 to 
999999 
 
 8 
[C] [2]  [0] [1] to [1] [F]  Writing M code of each point table 
This command will be available in the future. 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
0 to 99 
 
 
[C] [6]  [0] [1] to [1] [F]  Writing speed data of each point table 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
0 to 
permissible 
speed 
 
 
[C] [7]  [0] [1] to [1] [F]  Writing acceleration time constant of each point table 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
0 to 20000 
 
 
[C] [8]  [0] [1] to [1] [F]  Writing deceleration time constant of each point table 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
0 to 20000 
 
 
[C] [A]  [0] [1] to [1] [F]  Writing dwell of each point table 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
0 to 20000 
 
 
[C] [B]  [0] [1] to [1] [F]  Writing auxiliary function of each point table 
The data No. (hexadecimal) value which is converted to 
decimal corresponds to the point table No. 
0 to 3, 8 to 11 
 
 
 
(10)  General purpose register (Rx) value (command [B] [9]) 
 
Command  Data No.  Description  Setting range 
Control 
mode 
Frame 
length 
CP CL 
[B] [9]  [0] [1]  Writing general purpose register (R1) value 
Varies 
depending on 
the commands 
(Refer to 
section 5.2.2.) 
 
 
8 
  [0] [2]  Writing general purpose register (R2) value   
 
  [0] [3]  Writing general purpose register (R3) value   
 
  [0] [4]  Writing general purpose register (R4) value   
 
 
(11)  General purpose register (Dx) value (command [B] [A]) 
 
Command  Data No.  Description  Setting range 
Control 
mode 
Frame 
length 
CP CL 
[B] [A]  [0] [1]  Writing general purpose register (D1) value 
Varies 
depending on 
the commands 
(Refer to 
section 5.2.2.) 
 
 
8 
  [0] [2]  Writing general purpose register (D2) value   
 
  [0] [3]  Writing general purpose register (D3) value   
 
  [0] [4]  Writing general purpose register (D4) value