2. SIGNALS AND WIRING 
2 -  24 
 
(2)  OVR (Analog override selection) 
Enable or disable VC (Analog override). 
Analog
override
OVR (Analog override selection)
VC (Analog override)
-10 V to +10 V
Servo
motor
Servo amplifie
Position
control
Speed
control
 
Select a changed value by using OVR (Analog override selection). 
 
(Note) External input signal  Speed change value 
0 No change 
1  Setting of VC (Analog override) is enabled. 
 
Note. 0: Off 
1: On 
 
(3)  Analog override offset ([Pr. PC37]) 
You can set an offset voltage to the input voltage of VC (Analog override) with [Pr. PC37]. The setting 
value ranges from -9999 to +9999 [mV].