3. DISPLAY AND OPERATION SECTIONS
3 - 12
The following is additional information of alarm occurrence:
(1) The current alarm is displayed in any mode.
(2) Even during an alarm occurrence, the other display can be viewed by pressing the button in the
operation area. At this time, the decimal point in the fourth digit remains blinking.
(3) Remove the cause of the alarm and clear it in any of the following methods. (Refer to chapter 8 for the
alarms that can be cleared.)
(a) Cycle the power.
(b) Press the "SET" button on the current alarm display.
(c) Turn on RES (Reset).
(4) Use [Pr. PC18] to clear the alarm history.
(5) Press the "UP" or "DOWN" button to move to the next history.