4. HOW TO USE THE POINT TABLE 
4 -  7 
 
No. Start-up sequence  Fault  Investigation Possible cause Reference 
3  Perform a home 
position return. 
Servo motor does not 
rotate. 
Check the on/off status of the 
input signal with the external I/O 
signal display. (Refer to section 
3.1.7.) 
LSP, LSN, and ST1 are off. 
Section 
3.1.7 
Check [Pr. PA11 Forward 
rotation torque limit] and [Pr. 
PA12 Reverse rotation torque 
limit]. 
Torque limit level is too low for 
the load torque. 
Section 
7.2.1 
When TLA (Analog torque limit) 
is usable, check the input voltage 
on the status display. 
Torque limit level is too low for 
the load torque.  
Section 
3.1.2
 
The home position 
return is not completed. 
Check the on/off status of input 
signal DOG with the external I/O 
signal display. (Refer to section 
3.1.7.) 
The proximity dog is set 
incorrectly. 
Section 
3.1.7
 
4  Switch on ST1 
(Forward rotation 
start) or ST2 
(Reverse rotation 
start). 
Servo motor does not 
rotate. 
Check the on/off status of the 
input signal with the external I/O 
signal display (section 3.1.7). 
LSP, LSN, and ST2 are off. 
Section 
3.1.7
 
Check [Pr. PA11 Forward rotation 
torque limit] and [Pr. PA12 
Reverse rotation torque limit]. 
Torque limit level is too low for 
the load torque. 
Section 
7.2.1 
When TLA (Analog torque limit) is 
usable, check the input voltage on 
the status display. 
Torque limit level is too low for 
the load torque. 
Section 
3.1.2
 
5 Gain adjustment  Rotation ripples (speed 
fluctuations) are large 
at low speed. 
Make gain adjustment in the 
following procedure. 
1.  Increase the auto tuning 
response level. 
2.  Repeat acceleration and 
deceleration several times to 
complete auto tuning. 
Gain adjustment fault  MR-JE-_A 
Chapter 6 
Large load inertia 
moment causes the 
servo motor shaft to 
oscillate side to side. 
If the servo motor may be driven 
with safety, repeat acceleration 
and deceleration three times or 
more to complete the auto tuning. 
Gain adjustment fault  MR-JE-_A 
Chapter 6 
 
Note. Only a list of alarms and warnings is listed in chapter 8. Refer to "MELSERVO-JE Servo Amplifier Instruction Manual 
(Troubleshooting)" for details of alarms and warnings.