4. HOW TO USE THE POINT TABLE 
4 -  12 
 
(2) Point table 
(a) Point table setting 
1 to 31 point tables can be set. To use point table No. 4 to 31, enable DI2 (Point table No. selection 
3) to DI4 (Point table No. selection 5) with "Device Setting" on MR Configurator2. 
Set point tables using MR Configurator2 or the operation section of the servo amplifier. 
The following table lists what to set. Refer to section 4.2.2 for details of the settings. 
 
Item Main description 
Position data  Set the position data for movement. 
Servo motor 
speed 
Set the command speed of the servo motor for execution of positioning. 
Acceleration 
time constant 
Set the acceleration time constant. 
Deceleration 
time constant 
 Set the deceleration time constant. 
Dwell   Set the waiting time when performing automatic continuous operation. 
Auxiliary function  Set when performing automatic continuous operation. 
M code 
The first digit and the second digit of the M code are outputted in 4-bit binary 
respectively. 
M code will be available in the future. 
 
(b)  Selection of point tables 
 Using the input signal or the communication function, select the point table No. with the 
communication command from the controller such as a personal computer. 
The following table lists the point table No. selected in response to the input signal and the 
communication command. 
However, when using the input signal to select the point table No., you can only use point table No. 1 
to 3 in the initial status. 
To use point table No. 4 to 31, enable DI2 (Point table No. selection 3) to DI4 (Point table No. 
selection 5) with "Device Setting" on MR Configurator2. 
When using the communication function to select the point table No., refer to chapter 10. 
  
Input signal (Note 1)  
Selected point table No. 
DI4  
(Note 2) 
DI3 DI2 DI1    DI0  
0 0 0 0 0  0 (for home position return) 
0 0 0 0 1  1 
0 0 0 1 0  2 
0 0 0 1 1  3 
0 0 1 0 0  4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1 1 1 1 0  30 
1 1 1 1 1  31 
 
Note   1.  0: Off 
1: On 
    2.  DI4 is available only with the communication function. This device cannot be 
assigned as an input signal.