4. HOW TO USE THE POINT TABLE 
4 -  14 
 
(b) Parameter setting 
Set the following parameters to perform automatic operation. 
 
1)  Command method selection ([Pr. PT01]) 
Select the absolute value command method as shown below. 
[Pr. PT01]
0
Absolute value command method
 
2)  Rotation direction selection ([Pr. PA14]) 
Select the servo motor rotation direction when ST1 (Forward rotation start) is switched on. 
 
[Pr. PA14] setting 
Servo motor rotation direction when ST1 
(Forward rotation start) is switched on 
0 
CCW rotation with + position data 
CW rotation with - position data 
1 
CW rotation with + position data 
CCW rotation with - position data 
 
CW
CCW
 
3)  Position data unit ([Pr. PT01]) 
Set the unit of the position data. 
 
[Pr. PT01] setting  Position data unit 
_ 0 _ _  mm 
_ 1 _ _  inch 
_ 2 _ _  degree 
_ 3 _ _  pulse 
 
4)  Feed length multiplication ([Pr. PT03]) 
Set the feed length multiplication factor (STM) of the position data. 
 
[Pr. PT03] setting 
 Position data input range   
[mm]  [inch]  [degree] (Note 1)   [pulse] (Note 1) 
_ _ _ 0  - 999.999 to + 999.999  - 99.9999 to + 99.9999     
_ _ _ 1  - 9999.99 to + 9999.99  - 999.999 to + 999.999 
- 360.000 to + 360.000 
(Note 2) 
- 999999 to + 999999 
_ _ _ 2  - 99999.9 to + 99999.9  - 9999.99 to + 9999.99 
_ _ _ 3  - 999999 to + 999999   - 99999.9 to + 99999.9     
 
Note   1.  The feed length multiplication setting ([Pr. PT03]) is not applied to the unit multiplication factor. 
djust the unit multiplication factor in the electronic gear setting ([Pr. PA06] and [Pr. PA07]). 
    2.  The "-" sign has different meanings under the absolute value command method and the incremental value command method. 