Scenarios
• The Override button can be pressed when all of the following
conditions are satised.
• IMM is in manual mode; e.g., the Automatic Mode input signal is 0.
• The Machine OK signal is 1.
• The console is in Run, Standby, or Startup mode.
• The alarm severity is less than a fault; i.e., none of T/C, Triac,
Fuse, Power Limit, Ground errors.
• When the Override button is pressed, the Enable Mould Closure signal
will stay active for the time entered in the Override Time setting.
• After the timer elapses, the Enable Mould Closure signal becomes
inactive.
• If the Override button is pressed while an override is active, the
override time remaining is set to the length of time in the Override
Time setting.
• Override is canceled when any of the following conditions are
satised.
• The console mode is changed.
• The Automatic Mode signal is received from the IMM.
• The machine OK signal is lost.
• Override is NOT canceled when
• switching from Run to Standby mode when it is done automatically
from the delay of the automatic mode signal being switched to 0,
or
• there is a severe alarm; e.g., none of T/C, Triac, Fuse, Power
Limit, Ground errors.