39
07
Bulk charging
voltage
(C.V voltage)
Default setting: 56.0V
Setting range is from 48.0V
to 60.0V. Increment of each
click is 0.1V.
08
Floating
charging
voltage
Default setting: 54.0V
Setting range is from 48.0V
to 60.0V. Increment of each
click is 0.1V.
09
Low DC cut off
battery voltage
setting when
grid is
available
Default setting:42.0
Setting range is from 40V to
60V. Increment of each click
is 0.1V.
10
Battery re-
discharging
voltage when
grid is
available.
Default setting:48.0
Setting range is form 40V to
60V. Increment of each click
is 0.1V
11
Low DC cut off
battery voltage
when grid is
unavailable.
Default setting:48.0
Setting range is from 42V to
60V voltage. Increment of
each click is 0.1V
12
Battery re-
discharging
voltage when
grid is
unavailable
Default setting:54.0
Setting range is from 42V to
60V voltage. Increment of
each click is 0.1V
13
Operation
Mode
Grid-tie with backup
PV power can feed-in back to
grid, provide power to the
load and charge battery.
Off-Grid
PV power only provides
power to the load and
charge battery. No feed-in
back to grid is allowed.
Grid-Tie
PV power only can feed-in
back to grid.