LCD Screen Return To
Default Display
If selected, no matter how users switch
display screen, it will automatically return
to default display screen (Input voltage
/output voltage) after no button is
pressed for 1 minute.
If enabled, fault code will be recorded in
the inverter when any fault happens.
If selected, solar energy is allowed to
feed to the grid.
Set solar power as priority to charge the
battery or to power the load.
If clicked, PV energy storage data will be
reset.
Start Time For Enable
AC Charge Working
The setting range of start charging time
for AC charger is from 00:00 to 23:00.
The increment of each click is 1 hour.
Ending Time For Enable
AC Charge Working
The setting range of stop charging time
for AC charger is from 00:00 to 23:00.
The increment of each click is 1 hour.
Scheduled Time For AC
Output On
The setting range of scheduled time for
AC output on is from 00:00 to 23:00. The
increment of each click is 1 hour.
Scheduled Time For AC
Output Off
The setting range of scheduled time for
AC output off is from 00:00 to 23:00. The
increment of each click is 1 hour.
Country Customized
Regulations
Select inverter installed area to meet
local regulation.
This function is to restore all settings back to default settings.