87
Bulk Charging Voltage
Set battery bulk charging voltage
Battery Float Voltage
Set battery floating charging voltage
Max Charging Current
To configure total charging current for
solar and utility chargers.
Max AC Charging
Current
Set maximum utility charging current
Charging Source
Priority
To configure charger source priority
Back To Grid Voltage
Set battery voltage to stop discharging
when grid is available
Back To Discharge
Voltage
Set battery voltage to stop charging
when grid is available
Enable/Disable
Functions
Overload Auto Restart
If disabled, the unit won’t be restarted
after overload occurs.
Overload Temperature
Auto Restart
If disabled, the unit won't be restarted
after over-temperature fault is solved.
Overload Bypass
If enabled, the unit will enter bypass
mode when overload occurs.
Beeps While Primary
Source Interrupt
If enabled, buzzer will alarm when
primary source is abnormal.
Buzzer
If disabled, buzzer won’t be on when
alarm/fault occurred.
Backlight
If disabled, LCD backlight will be off
when panel button is not operated for 1
minute.