MAINTENANCE
Every 1000 hours of operation
The set of lters after 1000 operating hours can be or-
dered under the order number 4-760290. For the list of
all spare parts, see the table in the end of this publication.
3.6.21 Exchanging hydraulic oil and lter
First carry out after 500 hours.
• Replacing the hydraulic oil lter
• Remove the lter lid.
• Unlock the lter element.
• Lift the lter element out of the lter housing.
• Dispose of the lter element in an ecologically appropriate
manner.
• Place the new lter element in the proper position. Observe
the position of the locking cam.
• Turn the lter element fully clockwise to the stop.
Set of hydraulic oil lters
Order number: 1182946
• Lightly oil the sealing ring on the lter lid.
• Put the lter lid in place.
• Tighten the lid with atorque wrench (max. torque, 20 Nm).