RX1575 SERIES TRENCH ROLLER • OPERATION MANUAL S/N 3069933~ — REV. #0 (11/29/23) — PAGE 101
MAINTENANCE
111RAMMAX1575
555037
555038
555039
MAINTENANCE MANUAL
Every 1000 hours of operation
The set of lters after 1000 operating hours can be or-
dered under the order number 4-760290. For the list of
all spare parts, see the table in the end of this publication.
3.6.21 Exchanging hydraulic oil and lter
First carry out after 500 hours.
Replacing the hydraulic oil lter
Remove the lter lid.
Unlock the lter element.
Lift the lter element out of the lter housing.
Dispose of the lter element in an ecologically appropriate
manner.
Place the new lter element in the proper position. Observe
the position of the locking cam.
Turn the lter element fully clockwise to the stop.
Set of hydraulic oil lters
Order number: 1182946
Lightly oil the sealing ring on the lter lid.
Put the lter lid in place.
Tighten the lid with atorque wrench (max. torque, 20 Nm).