CARRIER SPECIFIC INFORMATION
MultiConnect
®
rCell 100 MTR-EV3 User Guide 23
again, or reset device in an attempt to regain control. Application should wait for a #9xx indication the process has
completed before proceeding.
Be aware after the HFA process is successfully completed the radio will be reset. The radio may also reset after
other OMA functions.
Sprint #9XX OMA Unsolicited Indications
#900 DM Client Ready
Sprint Hands Free Activation HFA Notifications
#901 HFA Attempt #
#902 HFA Countdown Timer (seconds)
#904 HFA Started
#911 HFA Error - credential error
#912 HFA Error - unreachable server
#913 HFA Error - network error
#914 HFA Done - HFA success
#922 HFA Done - No profile received
#923 HFA Error – ETC
#924 HFA Cancelled
#DREL Data session release
Sprint Network Initiated Device Configuration (NIDC) or Client Initiated Device Configuration (CIDC)
#906 DC - Session started
#911 DC - Error - credential error
#912 DC - Error - unreachable server
#913 DC - Error - network error
#915 DC - Error - update fails for other reasons
#918 DC - Done - success
#924 DC - Cancelled - no profile received
#DREL Data session release
Sprint Network Initiated or Client Initiated Preferred Roaming List (NIPRL or CIPRL) Download
#905 PRL - Session started
#909 PRL - Done - PRL success
#910 PRL - Done - No PRL update
#911 PRL - Error - credential error
#912 PRL - Error - unreachable server