INSTALLING THE ROUTER
28 MultiConnect
®
rCell 100 MTR-EV3 User Guide
The following is the default condition for the RESET button on the device. You can program a change to the
behavior of the button if needed.
To reset the device:
1. Find the hole labeled RESET. The reset button is recessed into the case.
2. Use the pin to press and release the RESET button as follows:
Reset options:
To reboot, press RESET for less than 3 seconds.
To reboot and restore user-defined defaults (if previously set), press RESET for 3 to 29
seconds.
To reboot, restore factory settings, and erase user-defined defaults, press RESET for 30
seconds or longer.
The device restarts in commissioning mode. The system automatically removes all user
accounts.
Enter a new username and password to create your new administrative account. (Refer to
User Accounts for more details on username and password requirements.)
Note: The device reboots when restoring settings.