5.1 Error Detection on EtherNet/IP module
5-1
Chapter 5 Error Detection
5.1 Error Detection on EtherNet/IP module
The current status of HMS EtherNet/IP module is indicated using up to four LEDs.
LED Dip switches Cable connector
LED2
LED3
LED1
LED4
Fig. 5.1.1 HMS EtherNet/IP module
Each LED indicates the following status for the slave module.
LED1: Network reception status
LED2: Current module status
LED3: Current communication status
LED4: Scanner status
Table 5.1.1 LEDs and field bus base board Status for the Slave Module
LED Color Status Description
Green Lit Online
LED1
Unlit Offline
Green Lit Run State Currently communicating with scanner
Green
Flashing
Not set / Idle State
Settings are not complete or no communication with
scanner
Red
Flashing
Error Non-critical error detected
Red Lit Error Critical error detected
LED2
Unlit No power supply
Green Lit
Online / Currently connected
Online
Green
Flashing
Online / Not connected Online / No communication partner
Red Lit Error Fatal error detected (duplicate IP address, etc.)
Red
Flashing
Error Non-critical error detected
Red green
Flashing
Self-diagnostics Currently performing self-diagnostics
LED3
Unlit Initialization incomplete / No power supply
LED4 Green
Flashing
Packet sending and receiving
Currently sending and receiving the packet