Service Processor 3-45
Table 3-35 HC Subcommands (cont’d)
cmd arg1 arg2 arg3 arg4 Description
cellx
on|off - - Turns on/off the LED of the CELL Board.
“x” is the physical CELL Board number (0-7).
led
(cont’d)
pcixx
on|off - - Turns on/off the LED of the Full/Half-size PCIX
Unit.
“x” is the physical PCIX Unit number (0-7).
When the PCIV is specified, all alarm LEDs are
turned on.
- - - - Used to specify location information manually.
Displays Help for “loc” when the argument is
omitted or an error is made.
This subcommand can be executed when all
partitions are in the DC POWER OFF state.
pbayxy d h
- Specifies the location and height of the Power
Bay Unit in the cabinet.
“x” is the cabinet number (0-1).
“y” is the Power Bay Unit number in the cabinet.
(0-2).
“d” is the position of the lower edge of the unit in
decimal (0-36) by using the EIA unit.
(1 EIA unit = 44.45mm)
“h” is the height of the unit (3,4).
loc
pcixx c d
l|r|f Specifies in which cabinet the Full/Half-size
PCIX Unit is located and the location of the unit
in the cabinet.
“x” is the PCIX Unit number (0-7).
“c” is the cabinet number (0-3).
“d” is the position of the lower edge of the unit in
decimal (0-36) by using the EIA unit.
(1 EIA unit = 44.45mm).
“l|r|f“ indicates the left, right, or both