I/O Board Installation 5-9
7. Replace the access cover (see Figure 5-5).
! Swing the cover back over the slots.
! Press the cover down and check that the cover latches are secured.
!
CAUTION
To prevent damage to the cover and chassis, check that the
cover is secured and can clear the chassis when you slide
the unit into the server.
8. Carefully press two rail latches (one on each side) and slowly slide the PCIX
unit back into the cabinet. Stop sliding if you feel resistance and check for
pinched or pulled cabling at the rear of the cabinet.
!
WARNING
Take care when releasing the latches and sliding the chassis
to avoid pinching your fingers.
A Right Rail Latch
Figure 5-6 PCIX Unit Rail Latches (right side shown)
9. Carefully and slowly slide the chassis all the way into the cabinet. Replace
the two screws to secure the PCIX unit (see Figure 5-4).