9-34 Upgrading Your Server
10. Check whether the installed 5.25-inch device is projected too much from the front of the
server.
Check the device installed in a 5.25-inch device bay based on the factory-installed DVD-
ROM drive.
11. Connect the interface and power cables to the 5.25-inch device installed from the left side
of the server.
See Chapter 10 for cable connection.
IMPORTANT: Connector pin bending or incomplete connection may
cause a malfunction to occur. Provide the connection securely watching
the 5.25-inch device and cable connectors.
NOTE: Make sure that the cable is not caught.
12. Install the removed components.
IMPORTANT: Pass the front cooling fan cables to the mother
board connector (see the figure).
To SCSI connector on
optional SCSI controller
Not used
Not used
To device installed in
slot 2 of 5.25-inch
device bay
Termination
connector
To device installed in
slot 3 of 5.25-inch
device bay