Upgrading Your Server 9-55
NOTE: Make sure of the orientation of the DIMM. The terminal side
of the DIMM has key and key slot to prevent incorrect insertion.
If the DIMM is inserted into the DIMM socket, the lever is automatically closed.
IMPORTANT: Install a pair of DIMMs at a time. In addition, use a
set of memory devices with the same specification. The specification of
a memory device is described on the label put on the DIMM.
6. Install the remove components.
7. Turn on the power of the server. Then make sure that any error message does not appear
in POST.
If an error message appears, write down the message and review the error message list in
Chapter 8.
8. Start SETUP to select [Advanced] [Memory Configuration] on menus. Then make sure
that the status of the additional DIMM is set to "Normal" (see Chapter 4).
9. Set [Reset Configuration Data] on the [Advanced] menu to "Yes".
This is required to update the hardware configuration. See Chapter 4 for details.
10. When the Windows operating system is used, set the paging file size to the recommended
value or larger.
Installed memory capacity × 1.5 (See Chapter 5.)