ESX Server Operation and Configuration 3-7
Select [ftServer] - [CPU Module] - [(primary)CPU Module(*)]. The screen of the CPU
Module(to be removed) will appear.
Select [CPU Module Start/Stop] - [Stop] to the stop of the CPU Module.
*As for the CPU module to be stopped, select [CPU Module(ID:0)] to stop CPU module 0,
select [CPU Module(ID:1)] to stop CPU module 1.
When the CPU module is stopped, the status LEDs change as follows. This indicates that one
CPU module is operating now.
[Indications of status LEDs during diagnosis]
LED Secondary* Primary*
1 CPU/IO module status LED1 Amber -
2 CPU/IO module status LED2 - Green blinking
*Here, an example where CPU module 0 is stopped is shown.
3. Start the stopped CPU module.
In the ft server utility, select the CPU module stopped in step 2 and click [Start] of [CPU
Module Start/Stop].
Once the CPU module is started, hardware diagnosis and then the duplication process are
performed.
Note that the system is paused temporarily for copying memory during memory
synchronization.