EasyManua.ls Logo

NEC Express5800 320Fd-MR - Evaluate Start and Stop of CPU Modules

NEC Express5800 320Fd-MR
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-6 ESX Server Operation and Configuration
Evaluate Start and Stop of CPU Modules
This section describes how to confirm the continuous system operation after stopping one of the
CPU modules.
1. Confirm that the CPU modules are duplicated.
To check if the CPU modules are duplicated, see the status LEDs of the CPU modules.
[Indications of status LEDs when CPU modules are duplicated]
LED
CPU module 0
(Operating)
CPU module 1
(Operating)
1 CPU/IO module status LED1 - -
2 CPU/IO module status LED2 Green Green
2. Use the ft server utility to stop the operation of the CPU module to be removed.
Move to the directory where the ft utility of NEC ESMPRO Agent is installed.
# cd /opt/nec/esmpro_sa/bin/
Start the ft server utility.
# ./ESMftcutil
The screen of the ft server utility will appear.

Table of Contents