EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 210

NEC NEAX 2000 IPS
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2 TROUBLESHOOTING
– 200 – NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-2ILCA (ILC) ACT0-1 lamp is
not on
Abnormal opera-
tion of No.0-1 cir-
cuit
Confirm the programming data:
CM06, CM10/CM14, CMAC.
Reset the system (Push the SW1 of
MP).
PAL0-1 lamp is
on
No.0-1 Line is
short-circuiting
Check to see if the Terminal Adapter is
correctly connected and the power is on.
B10/B11/B20/
B21 lamp is
Flashing (60 IPM)
Programming is
not set up
Confirm the programming data:
CM06, CM10/CM14, CMAC.
Reset the system (Push the SW1 of
MP).
PN-8IPLA
(IP-PAD)
RUN lamp is not
flashing
Abnormal opera-
tion of IP-PAD
card
Confirm the programming data:
CM0A.
Reset the MB switch.
(Down Up Down)
If the fault cannot be cleared,
replace the card.
L0 lamp is on LAN connection
failure
Check to see if the LAN cable is cor-
rectly connected.
LINK lamp is not
on
LAN connection
failure
Check to see if the LAN cable is
correctly connected.
Confirm the condition of the LAN
device (such as power of the HUB)
connected to the IP-PAD.
If the fault cannot be cleared,
replace the card.
1
2
1
2
1
2
3
1
2
3
JULY/01/2006
FAULT DIAGNOSIS AND TROUBLESHOOTING

Table of Contents

Other manuals for NEC NEAX 2000 IPS

Related product manuals