CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 13 – NWA-008847-001 Rev.3.0
a6ch1001.fm
DESCRIPTION DATA
CMEA
A
B
Continued on next page
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
Fault Kind: Occurrence 0
3
NONE
External Alarm Kind
0: Fault Memory
store/No output of
External Alarm
1: Fault Memory
store/External
Alarm is MN
alarm
2: Fault Memory
store/External
Alarm is MJ
alarm
3: Fault Memory
store/External
Alarm Kind is
determined by
standard data
No Fault Memory
store/No External
Alarm output
To assign NONE,
enter CCC.
01 System Initialization
NOTE 1
04 MP-FP/AP communication
failure
08 FP/AP card down
09 Power failure
12 CS/ZT fault occurred
16 Periodic maintenance
20 DTI line failure
21 DCH/BRT/PRT D-channel
link connection failure
22 CCH/IPT link connection
failure
24 Number of faulty trunks
was more than predeter-
mined number
[Australia Only]
NOTE 2
25 Number of lockout stations
was more than predeter-
mined number
NOTE 3
26 DLC card down
28
SMDR output buffer memo-
ry overflow
2B CS/ZT fault occurred
NOTE 4
2C LAN application fault
occurred
[Series 3400]
NOTE 5
~
JULY/01/2006
FAULT MESSAGE