CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 14 – NWA-008847-001 Rev.3.0
a6ch1001.fm
DESCRIPTION DATA
CMEA
B
C
Continued on next page
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
40 Traffic of IP network
exceeded limit bandwidth
[Series 3100]
0
3
NONE
External Alarm Kind
0: Fault Memory
store/No output of
External Alarm
1: Fault Memory
store/External
Alarm is MN
alarm
2: Fault Memory
store/External
Alarm is MJ alarm
3: Fault Memory
store/External
Alarm Kind is
determined by
standard data
No Fault Memory
store/No External
Alarm output
To assign NONE,
enter CCC.
41 Traffic of IP network
exceeded warning band-
width
[Series 3100]
42 Communication error
occurrence between Main
Site and Remote Site
[Series 3200 R6.2
(R6.2)]
NOTE 6
43 SIP fault occurred
[For PBC]
[Series 3600]
49 IP component reset
occurred
[Series 3500]
Fault Kind: Restoration
18 FP/AP card returned to nor-
mal condition
19 Power failure returned to
normal condition
30 DTI line returned to normal
condition
31 DCH/BRT/PRT D-channel
link connection returned to
normal condition
32 CCH/IPT link connection
returned to normal condi-
tion
34 Number of faulty trunks
was less than predetermined
number
[Australia Only]
NOTE 7
~
JULY/01/2006
FAULT MESSAGE

Table of Contents

Other manuals for NEC NEAX 2000 IPS

Related product manuals