CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 57 – NWA-008847-001 Rev.3.0
a6ch1001.fm
DESCRIPTION DATA
Assign the PBX number and Originating
Point Code for each center and local office.
•Y=02
(1) 0000-1023: PBX No.
(2) 00001-16367: Point Code set by
CMA7 Y=01
Assign which kind of fault information is
stored into the fault information memory,
and which kind of alarm is indicated.
•Y=2
(1) See “FAULT MESSAGE” of
(2) CHAPTER 1. Page 10
Specify the alarm kind sent automatically
to the Centralized MAT.
•Y=3
(1) 00 : MJ alarm
01 : MN alarm
02 : - - alarm
(2) 0 : Send
1 : Not sent
Specify the destination of fault information. Y=4
(1) 01 : Destination of fault information
(2) 2 : 2400 IPX MAT or Centralized
MAT
3 : 2400 IPX MAT or Centralized
MAT and RMAT
Specify the Point Code of the center office
as the Destination Point Code (DPC) which
fault information is sent to.
•Y=4
(1) 05: Destination Point Code of fault
information
(2) 00001-16367: Point Code of center
office
A
END
CMEA
CME3
CENTRALIZED MAT