CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 58 – NWA-008847-001 Rev.3.0
a6ch1001.fm
For Local Office
DESCRIPTION DATA
Assign the Originating Point Code (OPC)
for each local office.
NOTE: The Originating Point Code is
used to designate an originating
office in the CCIS/IPT network. A
single OPC should be assigned to
all CCH/IPT numbers provided
in the same office.
•Y=01
(1) 0-7: CCH/IPT No.0-7
(2) 00001-16367: OPC NOTE
Assign which kind of fault information is
stored into the fault information memory,
and which kind of alarm is indicated.
•Y=2
(1) See “FAULT MESSAGE” of
(2) CHAPTER 1. Page 10
Specify the alarm kind sent automatically
to the Centralized MAT.
•Y=3
(1) 00 : MJ alarm
01 : MN alarm
02 : - - alarm
(2) 0 : Send
1 : Not sent
Specify the destination of fault information. Y=4
(1) 01 : Destination of fault information
(2) 2 : 2400 IPX MAT or Centralized
MAT
3 : 2400 IPX MAT or Centralized
MAT and RMAT
START
CMEA
A
CMA7
CENTRALIZED MAT

Table of Contents