CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 65 – NWA-008847-001 Rev.3.0
a6ch1001.fm
(3) To set a time to execute the changeover (changeback) of the MP program, do the following
programming.
DESCRIPTION DATA
Specify the time for the changeover (change-
back) of MP program.
(1)
(2)
Y=51
01: Start time for changeover (changeback)
YYYY MM DD HH mm:
Changeover (changeback) time
YYYY : 2000-2099 (Year)
MM : 01-12 (Month)
DD : 01-31 (Date)
HH : 00-23 (Hour)
mm : 00-59 (Minute)
000000000000: Now executing
CCC : Clear
NONE : No data
NOTE1: For MP program changeover, the system is reset automatically. Be sure not to set the time
while the system is operating.
NOTE2: If a specified changeover time is passed while MP program is being downloaded, the
changeover of MP program is executed immediately (second data becomes
000000000000).
NOTE3: If you set the second data to 000000000000 while MP program is being downloaded, the
MP program changeover is executed after MP program download is completed.
NOTE4: If you set the second data to 000000000000 while matching the program version of Flash
ROMs, the MP program changeover is executed after the program version matching is
completed.
NOTE5: This data is cleared after MP program changeover is completed.
NOTE6: If the system is reset five times during about three minutes, the MP program changeback
is executed automatically.