CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 66 – NWA-008847-001 Rev.3.0
a6ch1001.fm
(4) To match the MP program version of Flash ROM 0 (outdated side) and Flash ROM 1 (upgraded
side), do the following programming.
(5) To read the status of MP program downloading, do the following programming.
DESCRIPTION DATA
Copy the MP program of Flash ROM 1 (up-
graded side) to the Flash ROM 0 (outdated
side).
NOTE1: You can clear the previous MP pro-
gram by this data setting.
NOTE2: While the MP program is being
downloaded, the second data 0 can-
not be assigned. If you do that,
“WAIT, BUSY NOW” is displayed.
•
(1)
(2)
Y=51
03
0 : To copy
1: Not copied
DESCRIPTION DATA
Read the status of MP program download.
NOTE: If you set this data other than while
the MP program download is exe-
cuted, “NONE” is displayed.
Display example:
If you are downloading the third file
of 11 MP program files, “00030B”
is displayed as the second data.
(File type 00=MP program file)
•
(1)
(2)
Y=51
04
XX YY ZZ
XX: File type
00: MP program file
YY: Downloading file No.
ZZ : Total number of files
START
CM0C
END
START
CM0C
END
JULY/01/2006
MP PROGRAM DOWNLOAD (FTP)