CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 85 – NWA-008847-001 Rev.3.0
a6ch1001.fm
To display whether command data is stored, and to clear the stored data in command buffer, do the
following programming.
DESCRIPTION DATA
Assign specification of particular data to out-
put.
(1)
(2)
Y=2
30: Specification of particular data for
command code of CMF6 Y=2>00
31: Specification of particular data for
command code of CMF6 Y=2>10
32: Specification of particular data for
command code of CMF6 Y=2>11
33: Specification of particular data for
command code of CMF6 Y=2>12
XXXZZ
XXX : 000-254: Byte location of com-
mand data
ZZ : 00-FF: Byte data
NONE : No data
NOTE: When setting this data, only the command of YY is output by XXXth byte of MP-FP com-
mand.
Assign Station number or Trunk number to
output Status Output.
(1)
(2)
Y=2
40: Status Output
X-XXXXXXXX: Station No.
DXXX : Trunk No.
XXX: 000-255
NONE : No data
DESCRIPTION DATA
Assign displaying the stored data in command
buffer and clearance of the stored data in com-
mand buffer.
(1)
(2)
Y=2
99: Displaying the stored data in command
buffer and clearance of the stored data
in command buffer
0 : No stored data
1 : Stored data remain
CCC: Clear the buffer
B
CMF6
END
START
CMF6
END
JULY/01/2006
ONLINE MP-FP COMMAND OUTPUT