2. Check to be sure message waiting lamp is enabled for the Subscriber Mailbox.
Program
Number
Program Name Description
47-02-08 Message Waiting Lamp
(Update MW Lamp)
Enter 1 (Yes) to enable Message Waiting lamp for each Subscriber
Mailbox.
By default, this option is 1 (Yes).
3. Set the maximum length of recorded messages left in the Subscriber Mailbox.
Program
Number
Program Name Description
47-01-03 Incoming Message Length
(Subs Msg Length)
Set the maximum length (1 ~ 4095 seconds) of recorded messages
for:
• Subscriber Mailbox users dialing RS to record and send a mes-
sage.
• Extension users leaving a message in a Subscriber Mailbox.
• Outside Automated Attendant callers accessing a mailbox via a
GOTO command and then dialing RS to record and send a mes-
sage.
• Subscriber Mailbox Greetings.
• Announcement Messages.
• Call Routing Mailbox Instruction Menus.
By default, these messages are a maximum of 120 seconds.
4. Set the maximum length of recorded Quick Messages left in the Subscriber Mailbox.
Program
Number
Program Name Description
47-01-04 Outgoing Message Length
(Mbox Msg Length)
Set the maximum length (1 ~ 4095 seconds) of recorded messages
for:
• Automated Attendant callers leaving a message or Quick Mes-
sage in a Subscriber Mailbox.
• Outside callers transferred by an extension user to a Subscriber
Mailbox.
By default, these messages are a maximum of 120 seconds.
Operation
Not applicable.
SL1100
ISSUE 3.5
2-228
Subscriber Mailbox
S