Chapter 7 Disk Array Configuration Setting
IV-32
4. A dialog box for changing the rebuild/expansion time of a pool appears.
Figure 7-28 Change Pool Rebuild/Expansion Time Dialog
Pool Information:
Number: Number of the pool
Name: Name of the pool
Rebuild Time: Current duration of time specified to rebuild the pool
Expansion Time: Current duration of time specified to expand the pool (selectable only when expanding
the pool)
Rebuild Time: Specify the duration of time to rebuild the pool.
Specify the duration of time to do rebuild if a physical disk becomes faulty in the disk
array. You can specify 0 to 24 hours. Although specifying 0 rebuilds the faulty disk in
the shortest time, select an appropriate time taking account of the load to the host I/O.
The time specified in the field is just a target, thus it is not assured to take the specified
time.