sudo /sf/rtfi/bin/sfrtfi_inplace
file:///upgrade/casper/filesystem.squashfs sf_upgrade=1
sf_keep_paths="/sf/packages/solidfire-sioc-4.2.0.2253
/sf/packages/solidfire-nma-1.4.8/conf /sf/packages/sioc
/sf/packages/nma"
The management node reboots with a new OS after the upgrade process completes.
9.
On the 12.2 management node, run the upgrade-mnode script to retain previous configuration settings.
If you are migrating from an 11.0 or 11.1 management node, the script copies the Active
IQ collector to the new configuration format.
a. For a single storage cluster managed by an existing management node 11.0 or 11.1 with persistent
volumes:
sudo /sf/packages/mnode/upgrade-mnode -mu <mnode user> -pv <true -
persistent volume> -pva <persistent volume account name - storage
volume account>
b. For a single storage cluster managed by an existing management node 11.0 or 11.1 with no persistent
volumes:
sudo /sf/packages/mnode/upgrade-mnode -mu <mnode user>
c. For multiple storage clusters managed by an existing management node 11.0 or 11.1 with persistent
volumes:
sudo /sf/packages/mnode/upgrade-mnode -mu <mnode user> -pv <true -
persistent volume> -pva <persistent volume account name - storage
volume account> -pvm <persistent volumes mvip>
d. For multiple storage clusters managed by an existing management node 11.0 or 11.1 with no persistent
volumes (the -pvm flag is just to provide one of the clusters MVIP addresses):
sudo /sf/packages/mnode/upgrade-mnode -mu <mnode user> -pvm <mvip for
persistent volumes>
10. (For all NetApp HCI installations and SolidFire all-flash storage installations with NetApp Element Plug-in
for vCenter Server) Update the vCenter Plug-in on the 12.2 management node by following the steps in the
Upgrade the Element Plug-in for vCenter Server topic.
11. Locate the asset ID for your installation using the management node API:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp HCI and is the answer not in the manual?

NetApp HCI Specifications

General IconGeneral
Product TypeHyperconverged Infrastructure (HCI)
Data ServicesData protection, encryption
Connectivity10 GbE, 25 GbE, 40 GbE, 100 GbE
Hypervisor SupportVMware vSphere
Management NodeIncluded in the solution
Storage MediaSSD and HDD
Node TypesCompute nodes, storage nodes
Storage ProtocolsiSCSI
Data ReductionDeduplication, compression, thin provisioning
High AvailabilityBuilt-in redundancy