Replace DC power supply units in H615C and H610S nodes
H615C and H610S nodes support two –48 V to –60 V DC power supply units. These
units are available as optional add-ons when you order H615C or H610S nodes. You can
use the these instructions to remove the AC power supply units in the chassis and
replace them with DC power supply units, or to replace a faulty DC power supply unit with
a new DC power supply unit.
What you’ll need
If you are replacing a faulty DC power supply unit, you have procured a replacement DC power supply unit.
If you are swapping out the AC power supply units in your chassis with DC units, you have taken into
consideration the downtime for the procedure.
You have an electrostatic discharge (ESD) wristband, or you have taken other antistatic precautions.
You have ensured that the power supply requirements are met:
Supply voltage: –(48-60) V DC
Current consumption: 37A (maximum)
Breaker requirements: 40A breaker
You have ensured that the materials in your environment adhere to the RoHS specifications.
You have ensured that the cable requirements are met:
One UL 10 AWG, 2 m maximum (stranded) black cable [–(48-60) V DC]
One UL 10 AWG, 2 m maximum (stranded) red cable [V DC return]
One UL 10 AWG, 2 m maximum green/yellow cable, green with a yellow stripe, stranded wire (safety
ground)
About this task
The procedure applies to the following node models:
One rack unit (1U) H615C compute chassis
1U H610S storage chassis
In the case of H615C and H610S, the terms "node" and "chassis" are used
interchangeably because node and chassis are not separate components, unlike in the
case of the 2U, four-node chassis.
You cannot mix AC and DC power supply units in your installation.
Steps
1. Turn off the power supply units and unplug the power cords. If you are replacing a faulty DC power supply
unit, turn off the power source and remove all the cables inserted into the blue connector.
2. Lift the cam handle, and press the blue latch to slide out the power supply unit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp HCI and is the answer not in the manual?

NetApp HCI Specifications

General IconGeneral
Product TypeHyperconverged Infrastructure (HCI)
Data ServicesData protection, encryption
Connectivity10 GbE, 25 GbE, 40 GbE, 100 GbE
Hypervisor SupportVMware vSphere
Management NodeIncluded in the solution
Storage MediaSSD and HDD
Node TypesCompute nodes, storage nodes
Storage ProtocolsiSCSI
Data ReductionDeduplication, compression, thin provisioning
High AvailabilityBuilt-in redundancy

Related product manuals