5. Select Yes in the confirmation dialog box.
6.
Select Browse to select the firmware image to upload, and select Upload Firmware.
Loading firmware from a location outside of the direct vicinity of the node might cause extended load times
and possible timeouts.
7.
Allow the preserve configuration checks, and select Start Upgrade.
The upgrade should take approximately 5 minutes. If your upload time exceeds 60 minutes, cancel the
upload and transfer the file to a local machine within the vicinity of the node.
If your session times out, you might see a number of alerts while attempting to log back in to the firmware
update area of the BMC UI. If you cancel the upgrade, you are redirected to the login page.
8.
After the update is complete, select OK, and wait for the node to reboot.
Log in after the upgrade, and select System to verify that the Firmware Revision version matches the
version you uploaded.
Find more information
NetApp HCI Resources page
SolidFire and Element Software Documentation Center
Replace H410S nodes
You should replace a storage node in the event of dual inline memory module (DIMM)
failure, CPU failure, Radian card problems, other motherboard issues, or if it does not
power on. Alarms in the VMware vSphere Web Client alert you when a storage node is
faulty. You should use the NetApp Element software UI to get the serial number (service
tag) of the failed node. You need this information to locate the failed node in the chassis.
What you’ll need
You have determined that the storage node needs to be replaced.
You have a replacement storage node.
You have an electrostatic discharge (ESD) wristband, or you have taken other antistatic precautions.
You have labeled each cable that is connected to the storage node.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp HCI and is the answer not in the manual?

NetApp HCI Specifications

General IconGeneral
Product TypeHyperconverged Infrastructure (HCI)
Data ServicesData protection, encryption
Connectivity10 GbE, 25 GbE, 40 GbE, 100 GbE
Hypervisor SupportVMware vSphere
Management NodeIncluded in the solution
Storage MediaSSD and HDD
Node TypesCompute nodes, storage nodes
Storage ProtocolsiSCSI
Data ReductionDeduplication, compression, thin provisioning
High AvailabilityBuilt-in redundancy

Related product manuals