Ê "config": {
Ê "force": false,
Ê "maintenanceMode": true
Ê },
Ê "controllerId": "a1b23456-c1d2-11e1-1234-a12bcdef123a",
Ê "packageName": "compute-firmware-12.2.109",
Ê "packageVersion": "12.2.109"
}
g. Click Execute to initiate the upgrade.
The upgrade cannot be paused after you begin. Firmware will be updated
sequentially in the following order: NIC, BIOS, and BMC. Do not log in to the BMC UI
during upgrade. Logging into the BMC terminates the Hybrid Cloud Control Serial-
Over-LAN (SOL) session that monitors upgrade process.
h.
Copy the upgrade task ID that is part of the resource link ("resourceLink") URL in the response.
4. Verify the upgrade progress and results:
a. Click GET /task/{task_id}/logs.
b. Click Try it out.
c. Enter the task ID from the previous step in task_Id.
d. Click Execute.
e. Do one of the following if there are problems or special requirements during the upgrade:
Option Steps
You need to correct cluster health issues due to
failedHealthChecks message in the response
body.
1. Go to the specific KB article listed for each
issue or perform the specified remedy.
2. If a KB is specified, complete the process
described in the relevant KB article.
3. After you have resolved cluster issues,
reauthenticate if needed and click POST
/nodes/{hardware_id}/upgrades.
4. Repeat the steps as described previously in
the upgrade step.
The upgrade fails and the mitigation steps are not
listed in upgrade log.
1. See this KB article (login required).
f. Run the GET /task/{task_id}/logs API multiple times, as needed, until the process is complete.
During the upgrade, the status indicates running if no errors are encountered. As each step
finishes, the status value changes to completed.
The upgrade has finished successfully when the status for each step is completed and the