67
CHAPTER 10
10. Specifications
10 Amp
20 Amp 40 Amp 65 Amp
QCW CW QCW CW QCW CW QCW CW
Output Current
Range (A) 0-9.5 0-10 0-19 0-20 0-38 0-40 0-62 0-65
Resolution (16 bit) (
µ
A) 153 305 610 992
Accuracy
1
±
(0.03% + 308
µ
A)
±
(0.03% + 615
µ
A)
±
(0.03% + 1.2 mA)
±
(0.03% + 2 mA)
Noise & Ripple
2
(rms) (mA) <10
Temperature Coefficient (ppm/
°
C FS) <200
Short Term Stability (1 hr) (ppm FS) <200
Long Term Stability (24 hrs) (ppm FS) <250
Compliance Voltage
3
Range (Volts) 1.5-29 1.5-30 1.5-14 1.5-15 1.5-7 1.5-8 1.5-4 1.5-5
Current Limit
Range (A)
0-10 0-20 0-40 0-65
Resolution (mA)
100
Accuracy (mA) 100
Pulse Width
4
Pulse Width Range (
µ
sec) 100 - 1000
Resolution (
µ
sec) 10
Accuracy
1
±
(2% +20
µ
s)
Transition Time
7
(
µ
sec) <40
Pulse over/under shoot (%Pk/
µ
s) <5/<200
Pulse “zero” current (% Pk) <1
Duty Cycle
4
Range
4
(%) 0.25 – 20
Pulse Repetition Rate
4
Range (Hz) 25 to 1000
Resolution (Hz) 1
Accuracy
1
±
(2% + 2 Hz)
Jitter (%) <10
1
± (% reading + fixed error).
2
True rms, 3 Hz to 300 kHz, ½ scale, resistive load.
3
Output requires a minimum voltage drop of 1.5 volts.
4
Applies only when operating in the QCW mode.
7
With Newport 1 meter cable: 10% to 90% of set current.