GEO S12 HARDWARE SETUP PROCEDURE Page 65/106
IMPORTANT
Ensure angle settings are identical on both sides of the cabinets.
Ensure that safety pins are properly locked into LS18s and GEO S12s connecting panels.
Ensure that all quick release pins are properly locked into their position.
Lift cluster to NS-1 defined rigging height, secure cluster horizontally to prevent it from
rotating;
Secure bumper with secondary safety steel.
IMPORTANT
The requirements for secondary safety systems vary with territories. However, the
secondary safety steel MUST have a SWL equivalent or greater than that of the rigging
system.