VBA10201-R.3577.A
- D4 -
2. Removal of Memory Compression PCB
M.C. PCB
CF PCB
M.C. PCB
CCD PCB Unit
Metal Frame
#812x2
#809
#809x3
CCD PCB connection harness
CCD PCB
CCD shield plate
Some bodies have a washer. (Red marking is
on the surface.)
When disassembling or replacing the CCD unit,
put the washer as it was.
Note: Few bodies have the screw for
broken thread in the position of the
screw #809.
(Red marking is on the screw.)