EasyManua.ls Logo

Nikon D100 VBA10201 - Image Adjustment Procedures

Nikon D100 VBA10201
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VBA10201-R.3577.A
- A44
-
8. Adjustment procedure
• CCD-EEPROM Flashram up
(1) Supply the power to the camera through the AC cable.
(2) Connect the USB cable to the camera.
(3) Select “CCD-EEPROM Flashram up” in “Contents” on the menu display.
(4) Press the START button. Perform the procedure according to the instructions on the screen.
(5) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG,NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(6) Remove the USB cable from the camera and then remove the AC cable.
• TFT-EEPROM Flashram up
(1) Supply the power to the camera through the AC cable.
(2) Connect the USB cable to the camera.
(3) Select “TFT-EEPROM Flashram up” in “Contents” on the menu dispay.
(4) Press the START button. Perform the procedure according to the instructions on the screen.
(5) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG,NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(6) Remove the USB cable from the camera and then remove the AC cable.
• Sensitivity adjustment
*Before adjustment, acquire the sensitivity reference value and color sensitivity ratio reference value by using
the reference body. (Refer to the next page for the procedure.)
(1) Set the luminance of the color viewer to “LV13”.
(2) Select “Sensitivity adjustment” in “Contents” on the menu display.
(3) Supply the power to the camera through the AC cable.
(4) Connect the USB cable to the camera.
(5) Set the tool lens (xed aperture is F8, with ND3 lter) onto the camera.
(6) Set the camera onto the luminance surface of the color viewer with nearest distance.
(7) Press the START button. Perform the procedure according to the instructions on the screen.
(8) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG,NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(9) Remove the USB cable from the camera and then remove the AC cable.
• CCD GrGb level compensation adjustment
*Before adjustment, acquire the sensitivity reference value and color sensitivity ratio reference value by using
the reference body. (Refer to the next page for the procedure.)
(1) Set the luminance of the color viewer to “LV13”.
(2) Set the color bar chart onto the color viewer.