Required device and conditions
※ AC adapter EH-6 and USB cable (mini B type) UC-E4 are used for all adjustments so they are not
particularly mentioned in the list.
※ For 5100K color viewer, ex-model viewer (J63049) is also available.
※ For color viewer/shutter tester, use luminance meter MB-3000 (J63068).
Item
Required device/condition
Color
viewer
【J63070】
Shutter
tester
【J19123】
Tool lens
(xed aper-
ture)
【J61185】
ND lter
(using commer-
cial product)
【J18191】
【J18358】
Color lter
【J63085】
【J63086】
【J63087】
Others
1
Gain dif. adj.among
channels
LV13 - F5.6 ND4×2 -
2 Stitching adjustment - LV12
F1.4
F8
- -
3
Sensi-
tivity
adj.
ISO200-800
LV13 - F5.6 ND8×2 -
ISO900-6400
LV13 - F5.6
ND8×2
ND4×
1
-
4 Shading adjustment - LV12 F8 - -
5
Gr/Gb compensation
adjustment
LV13 - F5.6 -
SP1 (B)
SP3 (R)
6
Sensitivity ratio adjust-
ment
- LV9 F5.6 - -
7
Sensitivity/sensitivity
ratio adjustment
LV13 - F5.6 - -
8
Pixel defect
compensation
Black
LV13 - F5.6 - -
9
White
- - - - -
Body cap or lens
cap, Environmental
temperature approx.
20 - 25℃
10
Tilt sensor inspection
and adjustment
- - - - -
F50/1.4D lens,
Tilted sensor
checking chart
11 TFT adjustment None
12 Obtain reference value Same as 3 (ISO200), 6, 7
13
Initial settings (factory
default settings)
None
14 Conrm adjusting data None
15 Version No./ Serial No. None