30 - Solution System 54Service Manual – SC250, Scrubtec 334, MA 30
Maintenance and Adjustments
Cleaning the Solution Tank and Filter
1. Ensure that the machine is off.
2. Remove the tanks container from the machine body using the handle.
3. Lift the tank cover and remove the solution cap.
4. Rinse the tank out with water
5. Remove the rubber gasket (A), then remove the lter strainer (B).
6. Clean them carefully and reinstall (C).
Figure 4
B
A
C