Revision 6
5.
After the stuffing bolts have been completely loosened, tap and carefully pry on the
stuffing box until it breaks loose from the fluid cylinder. Grasp the stuffing box and
remove it from the pump (Figure 8-5).
Figure 8-5. Removing the stuffing box from the pump.
Removal
and
Replacement
of
Plunger Packing:
6.
The stuffing box should be disassembled and overhauled in a clean workbench area.
Remove the packing spring from the end
of
the plunger. Pull the plunger out
of
the
stuffing box (Figure 8-6).
Figure 8-6. Pushing the plunger out
of
the stuffing box.
© Copyright October,
2001
NLB Corporation
8-1