RH-53/54
Nokia Customer Care
52 COMPANY CONFIDENTIAL 2005
Copyright © 2005 Nokia. All Rights Reserved.
Figure 42:TXP and TXC test points
General instructions for TX troubleshooting
Apply an RF-cable to the RF-connector to allow the transmitted signal act as normal. RF-cable
should be connected to measurement equipment or to at least a 10-dB attenuator, otherwise
the PA may be damaged.
Start Phoenix Service Software and:
Establish a connection to the phone e.g. FBUS.
Select->File
->Scan for product->CTRL-R
Select->
Testing ->
RFcontrols

Table of Contents