Steps
1. Cover the light guide (upper part of the A-Cover).
2. Start
Phoenix
.
3. Choose File→Scan Product.
4. Choose Tuning→Ambient Light Sensor Calibration.
Figure 36
Ambient Light Sensor Calibration
window
5. In the
Pull Up Resistor Calibration
pane, click Start, and Write.
6. In the
Ambient Light Sensor Calibration
pane, check the Use default values only check box, and click
Write.
7. To end the calibration, click Close.
RM-88
Nokia Customer Care BB Troubleshooting and Manual Tuning Guide
Page 6 –26 COMPANY CONFIDENTIAL Issue 1
Copyright © 2006 Nokia. All rights reserved.