1 General
BU 0155 en-3520 21
“Use 60/75°C copper field wiring conductors.”
„These products are intended for use in a pollution degree 2 environment“
“Maximum ambient temperatur 50°C”
“The source shall be derived from a non-corner grounded type TN with max. Impulse Voltage of 4 kV and not
exceeding 289 V phase to earth or from IT source with max. Impulse voltage of 6 kV not exceeding 500 V (or
equivalent) or devices with the suffix –IT.”
Size valid description
generally valid Only for use with Connectors from HARTING ELECTRIC GMBH & CO KG, LQ Mechatronic
Systems GmbH and Intercontec Produkt GmbH: “Suitable For Use On A Circuit Capable Of
Delivering Not More Than 5 000 rms Symmetrical Amperes, 500 Volts Maximum” “When
Protected by class RK5 Fuses or faster.
"Suitable For Use On
A Circuit Capable Of Delivering Not More Than ________ rms
Symmetrical Amperes, 500 Volts Max., When Protected by High-Interrupting Capacity, Current
Limiting Class CA, CC, CF, G, J, T Fuses.” The short circuit rating (max. 65 000A) is based on
the Connectors (Details listed below) and will be printed during production. Details listed in
1)
.
“Suitable For Use On A Circuit Capable Of Delivering Not More Than ______ rms Symmetrical
Amperes, 500 Volt maximum”
“When Protected by Circuit Breaker (inverse time trip type) in accordance with UL 489“ The
short circuit rating (max. 10 000) is based on the Connectors (Details listed below) and will be
printed during production. Details listed in
1)
.
installation
(Group fusing):
Only for use with Connectors from HARTING ELECTRIC GMBH & CO KG, LQ Mechatronic
Systems GmbH and Intercontec Produkt GmbH: “Suitable for motor group installation on a
circuit capable of delivering not more than 5000 rms symmetrical amperes, 500 V max” “When
Protected by class RK5 Fuses or faster, rated max. 30Amperes”, as listed below.
“Suitable for motor group installation on a circuit capable of del
_______rms symmetrical amperes, 500 V max” “When Protected by High-Interrupting
Capacity, Current Limiting Class CA, CC, CF, G, J, T Fuses, rated max. 30A”. The short circuit
rating (max. 65 000 A) is based on the Connectors (Details listed below) and will be printed
during production. Details listed in
1)
.
“Suitable for motor group installati
on on a circuit capable of delivering not more than
_______rms symmetrical amperes, 500 V max” “When Protected by Circuit Breaker (inverse
time trip type) in accordance with UL 489, rated max. 30 Amperes” The short circuit rating
(max. 10 0000) is based on the Connectors (Details listed below) and will be printed during
production. Details listed in
1)
.
differing data
CSA:
None differing data equal to UL