5 Parameter
BU 0155 en-3520 79
P131 Phase control mode FL
{ 0 }
Adaptation of the operating behaviour (running characteristics) of the motor
Value Meaning
0 Current-optimised
Optimisation of phase control for an even current flow. This
reduces the losses in the motor when starting up, but leads to an
increased tendency to oscillate in the event of long ramps and an
Optimisation of phase control for reduced tendency to oscillate with
idling motors or long ramps.
5.2.3 Motor data
P203 Rated motor current RF
0.50 … 18.80 A
Other applicable parameter(s) P130
The rated motor current is needed for I
2
t monitoring. For normal applications, the
setting corresponds to the nominal current as per the motor type plate.
As long as parameter P130=0 is set, the rated motor current is determined via the DIP
switch S1-DIP1...4. In this case the parameter can only be read, but not changed. It
then corresponds to the setting that is determined by the DIP switch.
P210 Start voltage RF
Other applicable parameter(s): P108, P130
The start voltage is the voltage that the device supplies immediately after setting the
enable at the motor terminals.
As long as parameter P130=0 is set, the rated motor current is determined via
potentiometer P2. In this case the parameter can only be read, but not changed. It
then corresponds to the setting determined by the potentiometer.
100.0 = the soft start is disabled.
P215 Boost voltage FL
Other applicable parameter(s): P210, P216
The boost voltage determines a boost to the start voltage in the starting phase. The
required breakaway torque is therefore provided for drives with increased starting
torque.
The boost voltage time is limited by P216.
P216 Time boost FL
Other applicable parameter(s): P102, P215
defines the time limit of the boost voltage (
) or the increased starting
torque.
The resulting acceleration time (T
total
), which achieved until full control of the voltage,
is calculated accordingly as: T
total
= T
P102
+ T