NORDAC LINK (SK 155E-FDS / SK 175E-FDS)Users Manual for Motor Starters as Field Distributors
26 BU 0155 en-3520
2 Assembly and installation
No options can be retrofitted. All options must be recorded by NORD when ordering and before the
production process. The customer must not open the device at any time and does not need to. The
device is mounted by using mounting lugs that are freely accessible from the outside. The electrical
connection of mains, motor and signal cables is only possible via respective plug connectors. The
optionally available control elements (e.g. switches) are mounted in a freely accessible position.
Opening a defined blind plug is only required for the temporary connection of a diagnostic tool. The
diagnostic tools comprise:
Parameterisation unit SK CSX-3H/ SK PAR-3H
NORDAC ACCESS BT with the NORDCON APP
PC with the NORDCON software
Various configurations of the FI can also be made during commissioning via the integrated DIP
switches or potentiometers. Access to these elements is also via the corresponding blank plugs.